Honeywell PhD6 5-Gas Detector

$1,470.00$2,625.00

Honeywell PhD6 5-Gas Detector is an extremely versatile gas detector with the capability of measuring up to 6 gases at once (uses 5 sensors), if such capability is needed.  Additional configurations are possible using a standard model and adding an additional sensor.  The PhD6 is designed to give you, the professional, the data you need with such ease-of-use  that technicians can operate the PhD6 without extensive training.

This product includes FREE SHIPPING.

PhD6 Ordering Information

The standard PhD6 configuration has a Li-ion battery pack with charger, datalogging and vibrating alarm. Alkaline battery packs can be added to any Li-ion powered PhD6. Some models can be ordered with Alkaline battery pack in place of the standard Li-ion (call).

The PhD6 can be configured with up to 5 sensors and with the DuoTox can read 6 gases. When considering sensor makeup, one location is reserved for an O2 sensor, a second location is reserved for LEL, either can be left unoccupied. The remaining 3 positions can carry any of the other sensors (currently 16).

To order or to discuss your requirements, we suggest calling SMG at 1-800-804-6196, emailing us at <sales@smglink.com> or using the contact form. Of the large number of available configurations over 375 are available as “standard”. Other configurations can usually be accommodated by ordering a standard configuration and adding selected sensor(s). For example order a 3-gas system and add a specific sensor to make the desired 4-gas configuration.

If you have unique or specialized requirements please call SMG at 1-800-804-6196 or email <sales@smglink.com> to discuss your needs.

Clear

Description

Honeywell PhD6 5-Gas Detector

Honeywell PhD6 5-Gas Detector is an extremely versatile gas detector with the capability of measuring up to 6 gases at once (uses 5 sensors), if such capability is needed. The PhD6 is designed to give you, the professional, the data you need with such ease-of-use  that technicians can operate the PhD6 without extensive training.

If you have unique or specialized requirements please call SMG at 1-800-804-6196 or email <sales@smglink.com> to discuss your needs.

PhD6 Features

The PhD6 has features that are incorporated or available as options with your requirements in mind.

  • 5 Sensor positions. Select from O2, LEL, PID and 16 toxic sensors
  • Uses the DuoTox 2-channel CO/H2S sensor to achieve 6-channel functionality
  • Field replaceable sensors
  • One button control of daily operations and true auto calibration
  • Calibration-due reminder
  • Sensor span reserve indicators during calibration for predictive maintenance
  • Standard black-box recorder stores a minimum of 63 hours of readings and associated data
  • Standard event logger stores specific data from alarm events
  • Standard datalogging (in addition to “black box” which is not user readable)
  • Standard vibrating alarm
  • Interchangeable alkaline and Li-ion battery packs (Li-ion standard)
  • Up to 24 hours battery life in either configuration
  • Drop-in fast charger/data dock
  • Recharges typically in less than 5 hours
  • Rugged polycarbonate case with TPE overmold
  • Easy-to-read top-mounted graphic display  with configurable backlight
  • Optional slip-on pump, software controlled
  • Optional pump powered by PhD6 battery
  • Automatic low-flow alarm
  • Automatic leak test before every use

PhD6 Approvals

Approvals from rating agencies assure you of a safe and reliable work-horse instrument.

  • UL Class I, Division 1, Groups A,B,C,D Temp Code T4
  • UL Class II, Division 1, Groups E, F, G
  • UL Class III
  • CSA Class I, Division 1, Groups A, B, C, D Temp Code T4
  • ATEX (DEMKO) EEx ia d llC T4
  • IECEx Ex ia d IIC T4
  • CE Mark
  • CQST (China) Ex ia d IIC T4

Durability (IP Rating): Meets IP65 water rating
RF Immunity: Conforms to EN 50270 per IEC 61000-4-3
RF Emissions: Conforms to IEC 61000-6-4
ESD Immunity: Conforms to IEC 61000-6-2

PhD6 Standard Accessories

Standard kit has the accessories needed to do the basic testing which include hand-aspirated manual sample-draw kit with 10 ft tubing, sample probe with dust and hydrophobic filters and spare filters, Li-ion battery pack with drop-in charging station (battery packs are interchangeable), belt clip, reference manual, laminated quick reference card, training CD-ROM, calibration adapter(s). Data logging and vibrating alarm are standard on most PhD6 models.

Frequently ordered accessories include the continuous sample-draw pump, 54-54-102, data logging, instrument part number with suffix D, (to read data requires either the optional  IQ6 Docking system, 54-54-9400N, or optional BioTrak software Kit, 54-54-0603 with IR Communication device (USB), 54-26-0605U) and data logging with vibrating alarm combination, instrument part number with suffix W.

PhD6 Ordering Information

The standard PhD6 configuration has a Li-ion battery pack with charger, data logging and vibrating alarm. Alkaline battery packs can be added to any Li-ion powered PhD6. Some models can be ordered with Alkaline battery pack in place of the standard Li-ion (call).

The PhD6 can be configured with up to 5 sensors and with the DuoTox can read 6 gases. When considering sensor makeup, one location is reserved for an O2 sensor, a second location reserved for LEL, either can be left unoccupied. The remaining 3 positions can carry any of the other sensors (currently 16).

To order or to discuss your requirements, we suggest calling SMG at 1-800-804-6196, emailing us at <sales@smglink.com> or useing the contact form. Of the large number of available configurations over 375 are available as “standard”. Other configurations can usually be accommodated by ordering a standard configuration and adding selected sensor(s). For example order a 3-gas system and add a specific sensor to make the desired 4-gas configuration.

This instrument kit has free shipping.

 

 

Additional information

Weight 3 lbs
Dimensions 12 × 8 × 6 in
Select combinations of gases monitored

NO, DuoTox(CO/H2S), NO2, IR-CO2, NO2, DuoTox(CO/H2S), IR-CO2, LEL, O2, Cl2, NH3, PID, LEL, O2, CO, Cl2, H2S, LEL, O2, CO, Cl2, H2S, SO2, O2, CO, Cl2, PID, LEL, O2, CO, H2S, HCN, LEL, O2, CO, H2S, IR-CH4, LEL, O2, CO, H2S, IR-CO2, LEL, O2, CO, H2S, IR-CO2, PID, O2, CO, H2S, NH3, LEL, O2, CO, H2S, NO, LEL, O2, CO, H2S, NO2, LEL, O2, CO, H2S, PH3, LEL, O2, CO, H2S, PID, LEL, O2, CO, H2S, SO2, LEL, O2, CO, NH3, IR-CO2, LEL, O2, CO, NH3, PID, LEL, O2, CO, NO, NO2, LEL, O2, CO, NO2, IR-CO2, LEL, O2, CO, SO2, NH3, LEL, O2, CO, SO2, NO, LEL, O2, CO, SO2, NO2, IR-CO2, O2,CO, SO2, NO2, LEL, O2, CO, SO2, NO2, PID, O2, DuoTox(CO/H2S), Cl2, LEL, O2, DuoTox(CO/H2S), HCN, LEL, O2, DuoTox(CO/H2S), IR-CH4, LEL, O2, DuoTox(CO/H2S), IR-CH4, PID, O2, DuoTox(CO/H2S), IR-CO2, LEL, O2, DuoTox(CO/H2S), NH3, LEL, O2, D'uoTox(CO/H2S), PID, LEL, O2, H2S, Cl2, CO-H, LEL, O2, H2S, CO-H, IR-CO2, LEL, O2, H2S, CO-H, NH3, LEL, O2, H2S, CO-H, PID, LEL, O2, H2S, NH3, SO2, PID, O2, H2S, NO, IR-CO2, LEL, O2, H2S, NO2, CO-H, LEL, O2, H2S, SO2, CO-H, LEL, O2, H2S, SO2, NH3, LEL, O2, H2S, SO2, NH3, PID, O2, H2S, SO2, NO2, HCN, O2, H2S, SO2, PID, LEL, O2, HCN, DuoTox(CO/H2S), LEL, O2, NO, DuoTox(CO/H2S), LEL, O2, NO, NO2, IR-CO2, LEL, O2, NO, NO2, NH3, PID, O2, NO2, Cl2, NH3, LEL, O2, NO2, DuoTox(CO/H2S), LEL, O2, PH3, DuoTox (CO/H2S), LEL, O2, PH3, HCN, IR-CO2, O2, SO2, Cl2, CO-H, LEL, O2, SO2, Cl2, NO2, NH3, O2, SO2, Cl2, PID, LEL, O2, SO2, DuoTox (CO/H2S), LEL, O2, SO2, NO, NO2, CO-H, O2, SO2, NO2, IR-CH4, PID, O2, SO2, NO2, PID, LEL, O2, SO2, CO-H, NH3, LEL