MesaLabs FlexCal Primary Flow Standard

$6,000.00

The FlexCal Primary Flow Standard is MesaLab’s newest standardized and volumetric flow standard. FlexCal’s have an accuracy of ±0.5% of reading (standardized) with flow rates from 5 ml/min to 50,000 ml/min combined with ease of use and portability.

Ordering Information

Select flow range: L (5 – 500 sml/min), M (50 ccm – 5 LPM),or H (0.5 – 50LPM)  from dropdown menu. The FlexCal kit includes the calibrator of the selected range, calibration caps, RS232 cable and manual. The optional Pelican-style case is an excellent addition for protecting your instrument.

Clear

Description

MesaLabs FlexCal Primary Flow Standard

The FlexCal Primary Flow Standard is MesaLab’s newest standardized and volumetric flow standard. FlexCal’s have an accuracy of ±0.5% of reading (standardized) with flow rates from 5 ml/min to 50,000 ml/min combined with ease of use and portability.

Features of FlexCal Primary Flow Standard

  • Flow ranges 5 to 50,000 ml/min
    • FlexCal-L: 5 – 500 ccm
    • FlexCal-M: 50 – 5000 ccm
    • FlexCal-H: 0.5 – 50 LPM
  • Accuracy ±0.5% of reading (standardized)
    • Volumetric, or
    • Standardized
  • Flow units L/min, mL/min, cc/min, cf/min
  • Pressure mmHg, PSI, kPa
  • Temperate: °C, °F
  • MFC gas sensor factor for calibration of gases other than air
  • Fittings: 1/4″ ID Swagelok compression tube (3/8″ Flexcal-H)
  • USB dataport
  • Quick start
  • Graphical LCD display
  • Intuitive interface
  • Field ready
  • RoHS compliant

FlexCal Ordering Information

Select FlexCal L, M or H flow range from drop-down menu. The FlexCal kit includes calibrator with selected flow range, calibration caps, manual, and USB cable. A protective Pelican-style case is an available option.

FlexCal Primary Standard Specifications

FlexCal-L FlexCal-M FlexCal-H
Flow ranges 5 – 500 ccm 50 ccm – 5 LPM 0.5 – 50 LPM
Accuracy* ±0.5% of rdg ±0.5% of rdg ±0.5% of rdg
Measurement units
Volumetric mL/min, L/min, cc/min, cf/min mL/min, L/min, cc/min, cf/min mL/min, L/min, cc/min, cf/min
Standardized smL/min, sL/min, scc/min, scf/min smL/min, sL/min, scc/min, scf/min smL/min, sL/min, scc/min, scf/min
Temperature °C  °F °C  °F °C  °F
Pressure mmHg, PSI, kPa mmHg, PSI, kPa mmHg, PSI, kPa
Temp and press sensor in flow stream in flow stream in flow stream
Approx time per reading 1-15 sec 1-15 sec 1-15 sec
Gas compatibility

non-corrosive, non-condensing, non-combustible, <70%RH

Flow models pressure or suction pressure or suction pressure or suction
Measurement cell style integral integral integral
Reading styles single (manual), continuous, burst with avg fnctn (1-100 measurements)
AC adaptor/charger

12VDC, >250 ma, center positive

Battery

6V rechargeable, sealed lead-acid, 6-8 hrs typical operation

Battery life (5 cycles/min)

3 hrs backlight on, 8 hrs backlight off

Pressure, suction fittings

1/4″ ID Swagelok,
3/8″ ID Swagelok on High range model

Warranty

1 year, battery 6 months

Storage temperature

0-70°C

Ambient humidity

0-70%, non-condensing

Operating pressure (absolute)

atmospheric, PSIA max

Display

backlit graphical LCD

Data port (PC interface)

USB

Data cable

1 meter (FlexCal data port to PC serial port)

MesaLabs meets the highest quality assurance standards for gas flow measurement, including industry-leading ISO 17025  laboratory accreditation by the National Voluntary, Accreditation Program (NVLAP). All primary measurements in Mesa’s lab are traceable to national standards maintained by the National Institute of Standards and technology (NIST).

Annual Service Package (purchased separately)

The annual service and calibration service includes full product refurbishment each time the instrument is returned including cleaning and replacing all filters and seals, and battery test and replacement if needed.  Any firmware or hardware upgrades are also installed at that time as part of the process. (Some upgrades may incur an extra charge) The calibration includes 3-point flow calibration. The NIST-traceable certificate returned with the instrument includes pre- and post- calibration data. These data are also stored in Mesa-Bios’ calibration database for future reference

Optional Accessories and Parts

100-250 Pelican case for 1 Defender or FlexCal
100-251 Pelican case for 2 or 3 Defenders or FlexCals
100-112 PC card to add serial port to laptop
100-450 1/4″ Barbed fitting
100-451 3/8″ Barbed fitting
100-432 Swagelok 3/8″ to 1/4″ reducer
100-222 Universal power supply/charger for Defender, Definer 220 and FlexCal
100-215 Optional plug for UK, EU or AUS service
100-113 RS232 serial cable
100-413 Leak test cap for 1/4″ barbed fittings (pkg 10)
100-428 1/4″ Swagelok ferrule
100-429 3/8″ Swagelok ferrule
100-444 1/4″ Swagelok nut and ferrule set
100-445 3/8″ Swagelok nut and ferrule set
100-406 1/4″ Swagelok leak test plug
100-407 3/8″ Swagelok leak test plug

 

Additional information

Select Flow Range

Flex-L, Flex-M, Flex-H